Alarms that Reach a Person who Confirmed They Want Them
An email subscription delivers nothing until somebody clicks its confirmation link, and until then every alarm publishes to a subscriber who is not there; repeat_notification_duration is null by default, so an alarm fires once at 3am and is never mentioned again. Creates the topic, subscriptions and alarms together, repeats while firing, and lists the subscriptions still waiting on a click.
Verification
Static-verifiedPassed: validated and lint-clean (provider-schema-validated for AWS/Azure/GCP; Terraform-language lint elsewhere).
Conformance
- Static validation (fmt · validate · tflint)
- Security scan clean (Checkov)
- Plan tests (mocked: validation rules · outputs)
Provenance
- SHA-256 checksum
- Signature (pending)
Functional
- Live test pending (no cloud run yet)
Last verified 2026-09-14 · how we verify
Use it from the registry
terraform · opentofumodule "monitoring_alarms" {
source = "www.iac-bazaar.com/iac-bazaar/oci-monitoring-alarms/oci"
version = "1.0.0"
}Needs a registry token from /account/tokens. The module itself is free; the account is what identifies you. Full setup: registry docs.
Inputs & outputs
Create a free account to read this module's contract
The declared contract - every input name, type, default and description, plus every output - is shown to signed-in accounts, not to anonymous visitors.
A free account sees the contract of every module in the catalogue. There is no subscription and nothing to buy - the modules are free to download, and they run under Vizier.
Documentation
oci-monitoring-alarms
Alarms whose notifications reach a person who has confirmed they want them.
Works with Terraform and OpenTofu (>= 1.6), oci provider
>= 8.0, < 9.0.
An email subscription delivers nothing until somebody clicks the
confirmation link. Creating it sends the email; until the link is
clicked the subscription sits in PENDING and every alarm that fires
publishes to a subscriber who is not there. This module cannot click it;
subscriptions_needing_confirmation lists the ones waiting.
An alarm with is_enabled = false evaluates nothing. Created enabled;
disabled needs accept_disabled_alarms.
An alarm that notifies once fires at 3am and is never mentioned again.
repeat_notification_duration is null by default in the API. Every alarm
here repeats hourly while firing unless accept_notify_once.
The topic is the destination. An alarm pointed at a topic with no
subscriptions fires into an empty room; refused without
accept_topic_without_subscribers.
Verification
Static validation runs tofu fmt, init, validate, tflint and checkov.
This module has not yet had a live test, so it is published as statically
validated with its live test pending and does not carry the live-tested mark.
Usage code & full reference need an account
The complete copy-paste usage, the full input/output reference, and operational notes are free with an account - shown here and bundled in the download. Sign in and this section fills in.
- Usage
Related modules
oci-service-connector
OCI Logging keeps a log for at most six months; a service connector from a log group to Object Storage is the archive, and it can be created INACTIVE, which is how one that was set up has moved nothing since. Created active, reads a whole log group so new logs are included, writes to a bucket, stream, function, topic, metric or Log Analytics, and exports the IAM statement the hub needs.
oci-logging
Every OCI service log is off until somebody turns it on: a VCN records no flow log, a load balancer no access log, a bucket no read log. Each log here is one service, one resource, one category, created enabled; a log created with is_enabled = false appears in the list and records nothing, and has to be accepted by name. Retention is 30 days by default and the shortest is reported.
oci-health-checks
A monitor can be created disabled and probes nothing; one vantage point reports the site down when that location is; and a monitor is a metric, not an alarm - nothing pages until Monitoring reads it. Enabled monitors over HTTPS from three regions by default, and the MQL query each one needs in an alarm exported for the oci-monitoring-alarms module.